Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM05484
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
09/07/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* - PROVIDE LISTING FOR USE OF 3" FLANGE INSIDE 4" PIPE - SUPPORT FLANGE ON FIRM BASE AND SECURE TO FLOOR W/SCREWS - UPC SECTIONS 316.3.1, 704.4.4 - UPC IS #9 SEC 314.2 PG 342 |
|
08/08/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* CODE REQUIRES FLANGES TO SET ON FF AND SECURED |
|
07/03/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* VENT FOR P-3 MISSING SAFETY PLATE INSTALL HANGER ON WATER SERVICE PIPING ABOVE CEILING |
|
07/02/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. OK TO COVER WALLS 2. DWV SUPPORTS OK 3. SUPPORT WATER PIPING AT CHANGES OF DIRECTION AND IN A MANNER THAT WILL ALLOW VALVE TO OPEN FULLY. 4. RECALL FOR CLOSET FLANGE INSP. AFTER FLOORING IS FINISHED. |
|
06/20/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* INSTALL SAFETY PLATES AT 4" VENTS LAV CARRIERS AND SUPPORT ON OVERHEAD PVC |
|
06/19/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV TEST THRU ROOF OK SUPPORT HORIZONTAL PLASTIC COMPLETE WATER FASTEN CLOSET FLANGES TO FLOOR, MUST BE INSTALLED ABOVE FINISHED FLOOR. |