Date Description Inspector Results Comments
11/08/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
1. OK TO COVER ALL AREAS
2. DO NOT ACTIVATE GAS UNTIL FURNACE IS SET

GAS IS ON
11/06/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. NEED TO SEE YARDWATER CONNECTIONS AT METER AND AT HOUSE.
2. GAS PRESSURE TEST OK
3. WATER HEATER OK
FURNACE NOT INSTALLED
4. INTERMEDIATE OK