Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM05449
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/14/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
11/23/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK TO COVER WALLS 2) RECEIVED LETTER ALLOWING ABS, ARMAFLEX AND TYPE "L" |
|
11/22/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1.UNLISTED HANGERS ARE NOT APPROVED. REVIEW 301 2003 UPC LISTED MATERIALS. 2. OK TO INSULATE HOT PER PLUMBING SPEC 2- PRODUCTS 2.2.2.7 PIPE INSULATION. 3. ABS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES, THEN NO MORE THAN 4' BETWEEN HANGERS. 4. OK FOR DRYWALL IN AREAS THAT DON'T HAVE HOT PIPING. |
|
11/20/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | PLAN CALLS FOR CAST IRON - INSTALLED IS ABS FEMALED THREADED ABS FITTINGS NOT PERMITTED IN ACCESSIBLE LOCATION. BLAKE TEE NOT PERMITTED IN ITS BACK. HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP. PLAN CALLS FOR TYPE "K" COPPER INSTALLED IS TYPE "L". RESCHEDULE FOR MONDAY. |