Permit: T06CM05438

Parcel: 141096040

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/21/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/20/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
12/14/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT PLUMBING WITHIN 1 1/2" OF PLATE SURFACE
2) NEED CITY OF TUCSON APPROVED TRUSS DRAWINGS
3) OSB ROOF SHEATHING MUST SPAN 2 BAYS-3 TRUSSES
4) RAIL READING 4 SEAMS IN ONE LOCATION ON ROOF NOT ALLOWED
12/11/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 2 NAILS REQUIRED IN ENDS OF DIAGONAL BRACES
2) NAIL PROTECT PLUMBING WITHIN 1 1/2" OF SILL PLATE EDGE
3) NO TRUSS DRAWINGS ON SITE
4) NO OSHA APPROVED LADDER ACCESS TO ROOF