Permit: T06CM05437

Parcel: 141351330

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM05437

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/16/2007 FRAMING Approved IVRS - Inspection :*
08/15/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ELECTRIC TO ISLAND OUT OF WALL
2) SHEARWALL AT KIT (SMART BOX) STUDS TO BE 16" ON CENTER FRAME AROUND OPENING AND NAIL AT H.D. NAIL DBL STUDS TO WALL AND AT AND AT 1ST FLOOR WEST BATH
3) TIGHTEN ALL A.B. NUTS, #5 SHEARWALL AT BATH A.B.'S AT 16" ON CENTER
4) FRAMING PLAN CALLS FOR DBL 2 X 12 DEN CEILING ? IS IT TO SUPPORT POP OUT ?
5) DUCT WORK INCOMPLETE 2ND FLOOR CEILING