Permit: T06CM05407

Parcel: 115061660


Addresses:

1800 N ORACLE RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/30/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
10/24/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. MAKE 2-WAY CLEANOUT TRAFFIC RATED
2. CLEANOUT MAY NOT BE DIRECTLY EMBEDDED IN CONCRETE
3. CLEANOUTS UNDE FRANK PATTERN COVER TO HAVE FEMALE THREADS AND AN APPROVED PLUG
4. SECURE ALL I.W PIPING
5. ALL ASPECTS OF PLUMBING FIXTURE SCHEDULE MUST BE MET OR SUPPLY PLAN REVISION
6. CONTINUED "NOT READY" WILL RESULT IN A
REINSPECTION FEE
10/23/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
- TRIM NOT INSTALLED PER PLAN
- ALL IN PIPING REQUIRES MINIMUM ONE INCH AIR GAP
- FLOOR SINKS REQUIRE GRADES AND STRAINERS
- STEAMER REQUIRES BACKFLOW PROTECTION
- ASME WATER HEATER REQUIRES ASME EXPANSION TANK
- PROVIDE CLEAN BACTERIA REPORT