Permit: T06CM05407

Parcel: 115061660


Addresses:

1800 N ORACLE RD

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/23/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
07/20/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER WALLS TO OVERHEAD
07/16/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. ABS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES, THRU NO MORE THAN 4' BETWEEN HANGERS.
SIMILAR FOR COPPER
NO PROVISION MADE FOR INSULATION
VERTICAL PIPE SUPPORT
2. U.G COPPER IS TYPE "L" WITH NO INSULATION ON THE HOT
3. GAS IN WALLS ONLY
WATER HEATER AND COOKING LINE