Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/26/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 03/28/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* INSTALL A HAMMER ARRESTOR FOR COLD WATER BRANCH SERVING URINALS. ALL RISERS HAVE CLEANOUTS. ALL CLEANOUTS WILL REQUIRE ACCESS. RELOCATION OF WATER SERVICE OK, EXCEPT DIELECTRIC UNION CANNOT BE CONCEALED UNDER WALK. EXTENT GALV TRANSITION TO AN ACCESSIBLE LOCATION. |
|
| 03/27/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 03/15/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 03/13/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* POST ADDRESS ON BUILDING |
|
| 03/08/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. INTERMEDIATE NOT READY 2. CALL FOR A ROUGH PLUMBING INSPECTION 3. REDLINES ON APPROVED PLANS DO SHOW THE ADDITION OF 2 FLOOR DRAINS. 4. REDLINES DO NOT SHOW DELETED WC OR HORIZONTAL VENTING. 5. ALSO, WASTE FOR MOP SINK NOT SIZED PER PLAN IT APPEARS THAT PLUMBER MAY INTEND TO WET VENT HORIZONTAL 2" WC VENT, THIS WOULD NOT BE ACCEPTED. 6. PROVIDE A PLAN REVISION SHOWING ACTUAL INSTALLATIONS, RED LINES WILL BE PARTIALLY ACCEPTED. |
|
| 03/02/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* ADD ROUGH SOIL TO PERMIT NOT INSTALLED PER PLAN PLAN DRAWN IN ERROR FLOOR DRAINS REQUIRED PER SEC 412.2.1 |