Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/05/2009 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* OK FOR SHEETROCK |
|
| 01/07/2009 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. GALV. PLUMBERS TAPE TOUCHING COPPER PIPING 2. PLATE STRAPS TOUCHING COPPER PIPING 3. PROVIDE PROPER CLEARANCE FOR B-VENT 4. B-VENT RUNNING THROUGH PLENUM NOT ALLOWED 5. NO COMBUSTIBLE MATERIALS ALLOWED IN PLENUMS 6. REPAIR ALL REFRIGERATION INSULATION 7. PROVIDE SCREEN AT COMBUSTION AIR AND RANGE HOOD |
|
| 12/03/2008 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |