Permit: T06CM05304

Parcel: 13113219B

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06CM05304

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/08/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
03/27/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE NOTE #1 2/28/08 INSPECTION

FAILURE TO COMPLY WITH NOTES FROM PAST INSPECTIONS WILL RESULT IN REFEE
03/26/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
LOCKED
CHECK CLEANOUT PLUGS AND T&P TERMINATIONS
ALSO, VENT TERMINATIONS
02/28/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE CORRECT DRAINAGE AT KITCHEN SINK
2. WASHER BOXES REQUIRE WATER HAMMER ARRESTORS
3. SEE NOTES FROM 2/14/08 INSPECTION & COMPLY
RECALL 03052 FOR INSPECTION WITH 03090
4. PROVIDE SIGNAGE IN ELECTRICAL BREAKER BOX STATING NON-BONDED PLASTIC WATER PIPING
5. PROVIDE CLEAN BACTERIA REPORT FOR WATER PIPING

LIST MAY NOT BE COMPLETE
02/08/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*