Permit: T06CM05304

Parcel: 13113219B

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESS TEST FNL

Permit Number - T06CM05304

Inspection Description - PLUMBING - GAS PRESS TEST FNL

Inspection Status - Approved

Date Description Inspector Results Comments
04/08/2008 PLUMBING - GAS PRESS TEST FNL Approved
02/14/2008 PLUMBING - GAS PRESS TEST FNL Partial Approval IVRS - Inspection :*
TEST OK

1. ALL UNITS REQUIRE MINIMUM 3' TERMINATION ABOVE TOP OF COMBUSTION AIR INTAKE AT ROOF FOR WATER HEATER AND FURNACE VENTS
2. DRYER GAS FLEXES REQUIRE PROOF OF LISTING
3. UPSTAIRS UNITS REQUIRE AIR TIGHT SEAL BETWEEN RETURN AIR PLENUM AND COMBUSTION AREA OF WATER HEATER/FURNACES