Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESS TEST FNL
Permit Number - T06CM05304
Inspection Description - PLUMBING - GAS PRESS TEST FNL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/08/2008 | PLUMBING - GAS PRESS TEST FNL | Approved | ||
02/14/2008 | PLUMBING - GAS PRESS TEST FNL | Partial Approval | IVRS - Inspection :* TEST OK 1. ALL UNITS REQUIRE MINIMUM 3' TERMINATION ABOVE TOP OF COMBUSTION AIR INTAKE AT ROOF FOR WATER HEATER AND FURNACE VENTS 2. DRYER GAS FLEXES REQUIRE PROOF OF LISTING 3. UPSTAIRS UNITS REQUIRE AIR TIGHT SEAL BETWEEN RETURN AIR PLENUM AND COMBUSTION AREA OF WATER HEATER/FURNACES |