Permit: T06CM05302

Parcel: 13113219B

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T06CM05302

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/08/2008 MECHANICAL - FINAL Approved IVRS - Inspection :*
03/26/2008 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
- PROVIDE AN OVERFLOW SENSOR ON SECONDARY DRAIN
OUTLET ON COIL AS PER SECTION 307.2.3 IMC
- IF USING PLASTIC KEEP MIN. 6" FROM VENT CONNECTOR
- PROVIDE PURPLE PRIMER ON ALL PVC FITTINGS PRIOR TO GLUE AS PER PLUMBING CODE
- INSULATE SHEETMETAL SLEEVE ABOVE COIL & SEAL BETTER
- TAPE NOT STICKING
- EXTEND FURNACE & WATER HEATER VENT MIN. 3' ABOVE COMBUSTION AIR INTAKE
- REMOVE ANY FOIL TAPE STUCK TO SHEETROCK
02/08/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE NOTES FROM UNIT #1