Permit: T06CM05297

Parcel: 13113219B

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Permit Number - T06CM05297

Inspection Description - MECHANICAL - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
10/18/2007 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
OK FOR SHEETROCK
10/12/2007 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
- DRYER VENTS NOT FITTING IN WALL
- DRYER VENTS OVALED TOO MUCH AT CONNECTION INTO DRYER BOX
- OK TO USE 3X4 DOWNSPOUT IN WALL
- RELOCATE WATER LINES CONTACTING FURNACE VENTS
- MUST HAVE MIN. 1" CLEARANCE
- PROVIDE PG FRAMES ON ALL SIDEWALL BOXES
- UNIT 5 PROVIDE SUPPLY TO BATHROOM
- PROVIDE BACKING ON ALL SIDEWALL REGISTER BOXES
09/28/2007 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
- INSULATE ALL SHEETMETAL DUCTS WITH MIN. R4.2 INSULATION WITH VAPOR BARRIER
- DO NOT USE SCREWS IN DRYER VENTS
- PROVIDE A PG FRAME FOR LOW COMBUSTION AIR
- PROVIDE MIN. 1" CLEARANCE FROM COMBUSTIBLES
AROUND B VENTS
- SOME DRYER VENTS INSTALLED BACKWARDS
- PROVIDE PLATE STRAPS AT DRYER VENTS WHERE NEEDED
- PROVIDE INSULATED COPPER CONDENSATE DRAINS AS PER PLANS
- OK TO USE ONE OPENING METHOD OF COMBUSTION AIR