Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T06CM05287
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/17/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
10/09/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) WITHIN 2 WEEKS: SECURE GAS PIPES IN BASEMENT 2) PROVIDE DRIP LEG AT WATER HEATER AND FURNACE 3) REPLACE FLEX LINES FOR GAS SUPPLY 4) DISCONNECT ROMEX AT BACK WALL OR REWIRE TO CURRENT CODE 5) RECEIVED AFTER HOURS INSPECTION-CHECK #1989 FOR $108.00 |