Permit: T06CM05285

Parcel: 121123210


Addresses:

5113 E FAIRMOUNT ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/17/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
10/12/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- USE OUTDOOR FITTINGS ONLY ON ELEC. CONDUIT.
- PROVIDE A ROOF JACK AT ROOF PENETRATIONS.
- SEAL ALL SCREW HOLES & SPOT WELD HOLES IN DUCT ON ROOF.
- PROPERLY SUPPORT DUCT ON ROOF.
- PROVIDE THE PROPER VENT ASSEMBLY FOR FURNACE.
- MUST USE 3/4" DRAIN PIPE ON CONDENSATE DRAIN.
- GLUE FITTINGS & TERMINATE WITHIN 6" OF THE GROUND & DIVERT THE WATER AWAY FROM THE HOUSE.
- BLOCK & CLAMP EVERY 4' & PAINT W/LATEX PAINT.
- DO NOT MOUNT ELEC. DISCONNECT ON A REMOVABLE PANEL.
- USE DUCT SEALER TO SEAL DUCTS NOT TAPE.
- LOW VOLTAGE WIRE MUST BE IN CONDUIT.
- EXPOSED DUCT ON ROOF REQUIRES R-8 DUCT LINE (2")
- PRESSURE TEST ON GAS PIPING
- PROVIDE 15 LB. GAUGE
- USE ONLY REDWOOD OR PRESSURE TREATED WOOD ON ROOF.