Permit: T06CM05276

Parcel: 13101071E


Addresses:

2222 S CRAYCROFT RD

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Date Description Inspector Results Comments
05/22/2007 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection :*
05/21/2007 PLUMBING - SEWER HCS CONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
WATER TEST FROM MAIN TO BUILDING OK
SHALL SEE CORRECT FALL JUST BEFORE END OF CURB
CLEANOUT AND CORRECT CONNECTION BETWEEN ABS SCH 40 AND SDR 35 PVC.
05/18/2007 PLUMBING - SEWER HCS CONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
SHALL PROVIDE MINIMUM 2% FALL PER APPROVED PLAN
WILL ACCEPT 1% BECAUSE OF STRUCTURAL CONDITION.