Permit: T06CM05260

Parcel: 11516028E

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/21/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
FLANGES OK
03/10/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. FLANGE IN EMPLOYEE RESTROOM OK
2. CLOSET FLANGES TO EXTEND 1/4" ABOVE FINISHED FLOOR
01/29/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
INSTALL FLANGES PER UPC SEC 316.3.1
WILL INSPECT AFTER FINISHED FLOOR
CODE HANDOUTS GIVEN AND EXPLAINED
12/14/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
SEE NOTE NUMBER 2 FROM 11/15/07
WATER NOT PER PLAN - OUTSIDE YARDWATER REQUIRED MINIMUM 12" COVER AT ALL POINTS. ALL FITTINGS AND CONNECTIONS TO BE EXPOSED. ALL PIPING WITHIN 1 1/4" OF THE STUD FACE TO BE PROTECTED.
12/14/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. ABS THRU ROOF OK
INSTALLED PER REDLINE
WATER TEST OK
2. COPPER INSTALLED PER REDLINES. YARD WATER PER REDLINE
3. NEED TO SEE FLANGES SCREWED DOWN
11/15/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
- INSTALL CLEANOUT AT WC'S, RED LINE CHANGE
- WATER NOT SIZED PER PLAN, NOT ROUTED PER PLAN
- LAV CARRIERS SPECIFIED
- WRAP PIPES PASSING THRU CONCRETE
- CLOSET FLANGES SHALL BE INSPECTED AFTER FINISHED FLOOR
08/28/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*