Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM05238

Parcel: 138180610


Addresses:

6756 S 6TH AV

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
10/18/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
10/16/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DRAWINGS SHOW 3" ABS TO SEWER IN FRONT OF HOUSE-NOT BUILT TO PLANS
10/12/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEGATIVE PITCH MAIN AFTER LAUNDRY
2) BED MAIN PROPERLY
3) INSPECTION DOES NOT INCLUDE 2 WAY CLEANOUT-NOT INSTALLED