Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06CM05224
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/11/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) RECEIVED (1) BACTERIA REPORT AND (3) IN HOUSE BACKFLOW CERTS |
|
| 05/09/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE #3 FROM 5/2/07 AND ALL BACKFLOW CERTIFICATIONS. 2. PROVIDE DRAINS, SEPARATE FULL SIZE TERMINATING AT FLOOR SINKS WITH 1" AIR GAP FOR ALL 009 BACKFLOW DEVICES, DRAINS TO BE PROPERLY SUPPORTED. LEFT GAS CARD |
|
| 05/08/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. COMPLETE LIST FROM 5/2/07 #3-#6 AND #8 2. PROVIDE DRAINS FOR BACKFLOW FOR (2) JUICE MACHINES AND SUPPORT. |
|
| 05/04/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* COMPLETE ALL WORK FROM 5/2/07 INSPECTION |
|
| 05/02/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. SEAL GAS PENETRATION THRU WALL TO METER 2. INSTALL HEAT TRAPS AT WATER HEATER PER PLAN AN INSULATE 1ST 8' IN AND 8' OUT OF WATER HEATER TO MEET 2003 ENERGY CONSERVATION CODE 3. SEE NOTE #9 P-001 PROVIDE CLEAN BACTERIA REPORT 4. INDIRECT DRAINS TO TERMINATE OVER RECEPTORS TO AVOID SPLASHING. 5. PROVIDE FULL SIZE WATER HEATER PAN DRAIN TERMINATING AT MOP SINK 6. PROVIDE BACKFLOW PROTECTION FOR WATER TO (2) JUICE MACHINES WITH CERTIFICATIONS ON ALL BACKFLOW DEVICES 7. PROVIDE ACCESS TO CLEANOUT FOR WASHER BOX 8. PROVIDE FACTORY TAPPED CLEANOUT PLUGS WITH MACHINE SCREWS. |