Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T06CM05219
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/25/2007 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
04/23/2007 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST UNDERGROUND & THRU TO 45 DEG. UP THRU ROOF PARTIAL APPROVAL. 1. SHALL SEE PIPE WRAPS 2. SHALL PROVIDE CORRECT DRAINAGE FITTINGS FOR P'3S NOTE: SHALL INSTALL BACKFLOW PROTECTION FOR CITY OF TUCSON FOOT SPA HANDOUT. |
|
01/19/2007 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PLAN IS APPROVED IN ERROR FOR YOUR APPLICATION, PROVIDE REVISED APPROVED PLAN FOR GRAVITY DRAIN FOOT SPAS, WITH PROVISION FOR CORRECT BACKFLOW DEVICE DRAINAGE PER HANDOUT GIVEN ON SITE. FLOOR PLAN OF RESTROOM TO BE REVISED & APPROVED. 2. PROVIDE CORRECT DRAINAGE AND DRAINAGE FITTINGS FOR SINK & LAV. 3. PROVIDE CORRECT TEST FITTING FOR UNDERGROUND APPLICATION NO ABS THREADED FITTING CAN BE IN AN UNACCESSIBLE LOCATION. 4. PLEASE HAVE PLUMBER ON SITE FOR NEXT INSPECTION. LIST NOT COMPLETE |
|
01/10/2007 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ONLY 1 P-TRAP IS ALLOWED ON ANY DRAIN ARM 2. EACH PLAN IS APPROVED IN ERROR IF THE FOOT SPAS ARE GRAVITY DRAIN. REVISE PLAN TO SHOW PROPER INSTALLATION FOR GRAVITY DRAINAGE AND PROVIDE FLOOR SINKS TO TERMINATE BACKFLOW DEVICES. 3. VENTING TO BE 6" ABOVE FLOOD RIM OF FIXTURE HAVE PLUMBER ON SITE FOR INSPECTION. 4. UNDERGROUND PIPING SHALL BE ON FIRM BEDDING THIS IS NOT A COMPLETE LIST. |