Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM05219

Parcel: 136406740


Addresses:

9660 E 22ND ST #140


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T06CM05219

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
04/25/2007 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
04/23/2007 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
WATER TEST UNDERGROUND & THRU TO 45 DEG. UP THRU ROOF PARTIAL APPROVAL.
1. SHALL SEE PIPE WRAPS
2. SHALL PROVIDE CORRECT DRAINAGE FITTINGS FOR P'3S

NOTE: SHALL INSTALL BACKFLOW PROTECTION FOR CITY OF TUCSON FOOT SPA HANDOUT.
01/19/2007 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PLAN IS APPROVED IN ERROR FOR YOUR APPLICATION, PROVIDE REVISED APPROVED PLAN FOR GRAVITY DRAIN FOOT SPAS, WITH PROVISION FOR CORRECT BACKFLOW DEVICE
DRAINAGE PER HANDOUT GIVEN ON SITE. FLOOR PLAN OF RESTROOM TO BE REVISED & APPROVED.
2. PROVIDE CORRECT DRAINAGE AND DRAINAGE FITTINGS FOR SINK & LAV.
3. PROVIDE CORRECT TEST FITTING FOR UNDERGROUND APPLICATION NO ABS THREADED FITTING CAN BE IN AN UNACCESSIBLE LOCATION.
4. PLEASE HAVE PLUMBER ON SITE FOR NEXT INSPECTION.

LIST NOT COMPLETE
01/10/2007 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. ONLY 1 P-TRAP IS ALLOWED ON ANY DRAIN ARM
2. EACH PLAN IS APPROVED IN ERROR IF THE FOOT SPAS ARE GRAVITY DRAIN. REVISE PLAN TO SHOW PROPER INSTALLATION FOR GRAVITY DRAINAGE AND PROVIDE FLOOR SINKS TO TERMINATE BACKFLOW DEVICES.
3. VENTING TO BE 6" ABOVE FLOOD RIM OF FIXTURE HAVE PLUMBER ON SITE FOR INSPECTION.
4. UNDERGROUND PIPING SHALL BE ON FIRM BEDDING

THIS IS NOT A COMPLETE LIST.