Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM05201

Parcel: 141313230

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM05201

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/09/2007 FRAMING Approved IVRS - Inspection :*
02/07/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FINISH LATH AT WALK DECK
2) EXTEND SHEAR INTERIOR
3) CRIPPLES AT INT. BEAM LEAD HT. STAIR CONCENTRATED LOAD
4) BLKS AT ROOF HIP BLKS, CUT TO SHORT OR NOT FITTING TIGHT