Permit: T06CM05201

Parcel: 141313230

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM05201

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/24/2007 EXT METAL CLIPS/EXT SHEATHING Approved
12/22/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
FROM LAST INSP. FRONT GARAGE WALL NOT STRAP
OR SHEAR REQ. PER PLAN
12/13/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) USE .148 DIAMETER SINKERS IN P.A.'S (USED SIMPSON BOOK) MY K.C. BOOK NOT LISTING FOR P.A. YOU INSTALLED
2) MISSING NAILING ON ROOF FRONT TWO PLACES MARKED 2ND FLOOR
3) CS 20 STRAP BOTH SIDES OF GARAGE HEADER, 19/SD4
4) ATTACH ALL GABLE END TRUSSES WITH LTP4'S 48" ON CENTER