Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM05191
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/30/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CHANGE OUT BEAM AT REAR 2) SUPPORT FLAT TRUSS AT GRADUATING HIP TRUSSES 3) FIND OUT IF ANY STRAPING REQUIRED AT 1ST TO 2ND FLOOR SHEAR |
|
| 11/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) NEED BLKS AT 4' ON CENTER 2/SD2 AT PARALLEL SITUATIONS 2) NEED 4 X 10 HEADER AT REAR SLIDER 3) PLAN SHOWS A3.5'S AT 24" ON CENTER TIE BETWEEN DRAG TRUSS AND DBL TOP PLT 4) SHIM ALL ROOF 3 PT BEARING TRUSSES AT REAR A02P AND GABLE 5) AT FRONT AND REAR WALLS, NAIL ALL 2ND FLOOR PLATES 6" ON CENTER 4/SD2 AT SHEARWALLS 6) TRUSS LYING FLAT FRONT HIP, MUST BE SUPPORTED |