Date Description Inspector Results Comments
11/04/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) NEED INFORMATION, ATTACHING SHEAR WALLS TO DRAG TRUSSES AT PARALELL SITUATIONS
2) STRAP FRONT AND BACK WALLS 4' ON CENTER 1ST & 2ND FLOOR
11/02/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CANNOT LOCATE ON PLAN, HOW 1ST FLOOR IS TO BE ATTACHED TO 2ND FLOOR
2) CAN'T FIND SHEAR TRANSFER CONNECTION, SHEARWALL TO ROOF, IN A PARALLEL SITUATION
3) NAIL #1 SHEAR TO FLOOR, AT PLATE 12" ON CENTER 16D'S #9 SHEAR, 4" ON CENTER TO FLOOR