Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM05187
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/14/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/13/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LOOSE NUTS, AT ALL H.D.'S 2) PEX TO CLOSE TO KITCHEN CANS 3) STAPLES IN POT. H20 & DWV 4) NEED DWV TEST 5) LOWER H.D. IN KITCHEN DOWN TO PLATE 6) BANG PLATE HALL BATH 7) SHIM HEADERS INTERIOR 8) INTERIOR SHEAR WALLS NAIL ALLS STUDS 9) CHECK ROMEX STAPLE 2ND FLOOR FRONT BED SOUTH EAST WALL 10) MORE NAILS 2ND FLOOR SHEAR 11) BLK MECH 2ND FLOOR CLOSET |
|
| 12/13/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) MISSING LOAD WINDOW 2) FRONT NOT FINISHED 3) POP-OUT FOAM NOT COVERED WEST SIDE 4) MISSING ANTI-SIPHON ON HOSE BIB |