Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM05187
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/30/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO WRAP AND DRY IN 2) NEED TO FINISH #4 & #5 ABOVE |
|
| 11/29/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) SEE #4 & #5 |
|
| 11/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) REAR 2ND FLOOR SHEAR, HORIZONTAL JOINTS NOT NAILED 2) FRONT COLUMN ATTACH TO BOTTOM PLATE 3) FRONT BOLTS HD8A NEED WASHERS ON WOOD SIDE 4) NAIL SHEAR AT GARGE BEAM 5) MISSING HANGERS AT ALL HIP LOCATIONS |