Permit: T06CM05176

Parcel: 129023010


Addresses:

2625 E CROYDEN ST


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM05176

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/12/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/24/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAILING APPROVED PENDING PLAN CHANGE
2) HAVE ROOF FRAMING PLAN APPROVED AS BUILT
3) ADD H2.5 CLIPS EACH END ALL RAFTERS AND TJI'S
4) PROVIDE FIREBLOCKING AT ALL FURR OUTS AT CEILING
5) INSTALL FURNACE B-VENT
6) INSTALL EXHAUST FAN TOILET AREA AND BATH
7) 01025 INSURE NAILING 6" ON CENTER EDGES AND 12" ON CENTER FIELD
8) NAIL OFF ALL PA STRAPS WITH 16D COMMONS ALL HOLES INTO STUDS
9) ADD RED HEADS INTERIOR BEARING WALLS
10) ADD CRIPPLES AND TIES WHERE REQUIRED