Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/29/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/16/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) PENDING HOLDOWN AT REAR PORCH AT BEDROOM DOOR JAMB
2) OK TO LATHE
02/15/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
COMPLY W/#2 & 4 BELOW
02/13/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 2 SW1 REQUIRED AT PATIO
2) HOLDOWN AT PATIO CUT OFF
3) SW2 MISSING AT FRONT PORCH
4) PLYWOOD SHEATHING 3/8" THICK OR LESS SHALL BE APPLIED WITH LONG DIMENSION ACROSS STUDS-TABLE R602.3(3) NOT B/C
5) STOPPED INSPECTION