Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T06CM05111
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/01/2007 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
01/24/2007 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 3" INTERCEPTOR VENT WATER TEST OK SHALL SEE INTERCEPTOR TEST AT LATER DATE 4" GREASE WASTE INTO INTERCEPTOR WATER TEST OK 2 1/2 T/K WATER STUB UP & OUT OF BUILDING OK |
|
01/23/2007 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 4" WATER TEST SANITARY DRAINAGE UNDERGROUND OK 4" GREASE WASTE TO BUILDING EXTERIOR WITH CLEANOUT WATER TEST OK 1. SHALL INSTALL GREASE INTERCEPTOR VENT PER PLAN AND SEE TEST ON INLET, OUTLET & INTERCEPTOR CONNECTIONS. |
|
01/22/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
01/19/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* TEST TO BE IN PLACE |