Permit: T06CM05084

Parcel: 126010290


Addresses:

4237 E KILMER ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/21/2007 FRAMING Approved IVRS - Inspection :*
03/16/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURE BRACING IN ATTIC TO EXISTING JOISTS
2) FRAME LOOSE AT HEADER AT REAR ROOM-CHECK ALL FRAMING
3) GROUND ALL METAL BOXES
4) MAKE UP ALL BOXES
5) CHECK CABLE FROM SUB PANEL TO SERVICE FOR GROUND
6) PROTECT ABS AND WATER LINES CLOSER THAN 1 1/4" TO FACE OF STUD
7) WASTE AND OVERFLOW NOT CONNECTING AT EXISTING TUB
8) REVISE PLAN TO REFLECT ELECTRIC W/H AND RELOCATION AND EXISTING SERVICE TO REMAIN PRIOR TO FINAL