Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/24/2008 | REINFORCED MASONRY PRE-GROUT | Approved | ||
| 02/25/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* OK TO GROUT DUMPSTER ENCLOSURE |
|
| 09/27/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ALL BUT DUMPSTER |
|
| 09/26/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LOADING DOCK NORTH & SOUTH WALL TO FULL HEIGHT EAST SCREEN WALL TO 4' |
|
| 06/26/2007 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE CONTINUOUSLY FROM SUPPORT AT ENDS OF WALLS AT LEAST ONE REBAR ON EACH SIDE OF CORNERS FROM FOUNDATION, IN ACCORDANCE WITH APPROVED PLANS VERTICAL REINFORCING ON TOP WALL ALL VERTICALS NEED TO COME FROM FOUNDATION AND NEED TO TRANSFER LOAD PATH TO FOUNDATION #4 @ 48" O.C OVERLAP WITH VERTICAL REINFORCING FROM FOUNDATION ON THESE MISSED REINFORCING PROVIDE EPOXY CONNECTIONS AND SPECIAL INSPECTION REPORT. VERIFY APPROPRIATE REINFORCING ON OPENINGS AND CONTROL JOINTS. NOT APPROVED TO GROUT |