Permit: T06CM05077

Parcel: 117141970


Addresses:

49 W KENNEDY ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/29/2009 EXT METAL CLIPS/EXT SHEATHING Approved
06/13/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*.
1) INSPECTED ALL OSB SHEATHING-OK STILL MISSING HARDWARE
10/01/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DRAWING CALLS FOR J-BOLTS AT SHEARWALL. J-BOLTS MISSING AND NOT IN RIGHT PLACES-NEED ENGINEER FIX