Permit: T06CM05065

Parcel: 113095180

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/01/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/27/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
GROUND METAL BOXES
MAKE UP SWITCHES PIG TAIL GROUNDS
SECURE ROMEX 8" FROM BOXES
CLIP SHIM TO EXISTING TOP PLATE
02/22/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LUS24 HANGERS UNDERSIZED PER PLAN
2) SCREW NAILS THROUGH HANGERS REQUIRED TO BE FULL LENGTH IN ORDER TO PENETRATE BEAM
3) 1" SEPERATION REQUIRED BETWEEN UNTREATED POSTS AND CONCRETE
4) BLOCKS UNDER NEW RAFTERS AT CONNECTION TO EXISTING STRUCTURE NEED TO BE CUT LONG ENOUGH TO FIT TIGHT BETWEEN EXISTING RAFTERS
5) KING STUDS NEEDED ON EITHER SIDE OF GARAGE DOOR HDR