Permit: T06CM05062

Parcel: 125121770


Addresses:

3302 E 3RD ST

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
05/04/2007 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
05/03/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH DETAILS 1/D1 AND 5/D1 FOYER DOWELS 24" ON CENTER INTO EXISTING 1 #3 BARS 16" ON CENTER
2) COMPLY WITH FIREPLACE DETAIL 35/D2 #5 BARS 8" ON CENTER EACH WAY
3) SPECIAL INSP OK SUPPLY AT FINALS
04/27/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) I HAVE INSPECTED JOB SCOPE-EVERTHING WAS INSPECTED EXCEPT FOR COLUMNS FOR POOL PATIO AREA. REBAR WAS OK FOOTER DEPTH AND WIDTH WAS OK. PERMIT IS REQUESTING SPECIAL INSPECTION FOR SITE PREPERATION. SO IF CONTRACTOR WANTS TO POUR FOOTERS HE CAN DO SO AT HIS OWN RISK BUT MUST HAVE SPECIAL INSPECTION AT FINAL