Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/13/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/08/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL SHEATHING TO DBL STUDS AT ALL HOLDDOWN LOCATIONS 2) PROVIDE ANCHOR BOLTS AT SHEAR PANELS PER PLAN 3) PROVIDE TRUSS SPECS 4) STOPPED INSPECTION |