Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM05043

Parcel: 13005312B


Addresses:

2125 E 35TH ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/08/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/26/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. STRONG WALL MISSING AT GARAGE JAMB
2. COMPLY WITH ENGINEER REQUIRMENT HOLDDOWNS AND SHEAR WALL FASTENERS.
3. SHEAR/BRACED PANELS SHALL BE NAILED TO TOP PLATE
4. NEED APPROVED TRUSS DRAWINGS
5. NAIL ROOF SHEATHING TO SOLID BLOCK