Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T06CM05015
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/22/2007 | ELECTRIC - FINAL | Approved | ||
08/16/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - REMOVE ALL COVERS IN QUESTION - ELEC. CONTR. NOT ON SITE |
|
07/30/2007 | ELECTRIC - FINAL | Cancelled | IVRS - RI canceled | |
06/13/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ELECTRICAL CONTRACTOR TO BE ON SITE FOR INSPECTION |
|
04/16/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CANNOT REMOVE PANEL COVER PAINTED & CAULKED TO WALL 2. LABEL CIRCUITS AT PANEL PER NEC 408.4 3. ALL KITCHEN COUNTERTOP RECEPTACLES TO BE GFI PROTECTED PER NEC 210.8 4. NO POWER TO REFRIGERATOR RECEPTACLE 5. INSTALL BOX EXTENSION ON RECEPTACLE UNDER SINK PER NEC 314.20 6. KITCHEN RECEPTACLES NOT WIRED PROPERLY 7. LENGTH OF CORD TO CONNECT DISHWASHER TO BE 3FT TO 4FT PER NEC 422.16 8. GROUND ALL SWITCHES PER NEC 404.9 |