| 11/16/2006 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | IVRS - RI canceled | |
| 11/15/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/13/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL OUTRIGGERS AND EAST BIRD BOARDS 2) NAIL WALL OSB WHERE NEEDED 3) LAG OR H2.5 PORCH LEDGER 4) STRAP BEAMS 5) STRAP SOUTH WALL TOP PLATES ACCROSS BEAM 6) STRAP GABLE TRUSS CORNERS DOWN TO KINGS |
|
| 11/09/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) DBL HANGER 2) ADD STUD UNDER GLU LAM 3) ADD H2.5'S TO LEDGER BOARDS |