Permit: T06CM04975

Parcel: 122171240


Addresses:

3414 E CAMDEN ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/02/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
09/12/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- 6 PSI ON 30 PSI GAUGE
- CHECK FOR LEAKS
- USE 15 PSI GAUGE WITH 1/10 PSI INCREMENTATIONS.
- CORRECT CRUSHED DRAFT CONNECTOR AT WH
- PROVIDE INCREASER AT 3" TO 4" VENT CONNECTION
- T&P SHALL TERMINATE TO EXTERIOR W/APPROVED MATERIALS, 6-24 INCHES ABOVE GROUND W/OUT THREADS.
- FURNACE VENT CONNECTOR SHALL BE GALVANIZED AND SECURED W/SCREWS. CORRECT VENT THROUGH ROOF. PROVIDE COMBUSTION AIR OPENINGS AT FURNACE.