Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T06CM04972

Parcel: 10713032A

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
08/23/2007 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
HAVE REVISED PLAN STAMPED BY PLAN REVIEWER
OK TO COVER, SUBJECT TO APPROVED PLAN
08/07/2007 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
ABS DWV UNDERGROUND FOR TOILET ROOMS AND WASHING MACHINE DRAINS AS INSTALLED PER P-1 CONFLICTS WITH 2003 UPC WHICH GIVES WASHING MACHINES IN GROUPS OF THREE OR MORE A DESIGNATION OF 6 DFU'S EACH
PLEASE REVISE PLAN AND SHOW CORRECT SIZING.