Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T06CM04953
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/20/2008 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
02/06/2008 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
01/09/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* BLDG #C1 CMU REINFORCEMENT STEEL @ GRID B.2/4.8 TO 5.2 FROM 4' TO 8' AFFE |
|
12/19/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU REINFORCEMENT STEEL @ GRID 3/B.2 TO 2 FROM 8' TO 12' |
|
12/03/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* BLDG C-1 CMU REINFORCEMENT STEEL @ GRID 6/B TO C FROM 8' TO 12' AND 6/B TO C FROM 12' TO 15'4" |
|
11/09/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU REINFORCEMENT STEEL @ GRID C/3 TO 4 - 4/C TO C.2 - 2.5/D TO E @ 20' TO 24' 4/C-C.2 @ 16' TO 20' - F.1/6.5 TO 8 - F.2/7 TO 8 G/3.2 TO 6.1 - F.1/6.5 TO 7 - F.2/7 TO 8 @ 4' TO 8' 3.2/H.1 TO H.5 - H.4/6.5 TO 7 - 6.1/F.2 TO G.2 @ 0' TO 4' AND G/3.2 TO 6.1 @ 8' TO 12' |
|
11/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU REINFORCEMENT STEEL @ GRID 4.5/G.2 TO E C.2/4 TO 4.5 20FT TO 24FT AFF - E/2.5 TO 4.5 - RM #328 N/E V HALL 16FT TO 20FT AFF 4.5/C.2 TO D & C.2/4 TO 4.5 16' TO 20' AFF & 4/C TO C.2 8' TO 12' AFF C/3 TO 6 - 8' TO 15'4" AFF & 4.2/C TO C.2 4' TO 8' AFF C/3 TO 6 4' TO 8'8" AFF & E/3 TO 4.2 -- 12' TO 16' AFF |
|
10/30/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* WILL RECALL FOR 31 OCT |
|
10/17/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* BLDG #C1 REINFORCEMENT STEEL IN CMU WALL @ GRID LINES C/3.2 TO 6 -- E/3.2 TO 4.2 - 4.2/C.8 TO E - 3.2/B TO C 4/C TO C.2 - FROM 0 TO 4 FOOT AFF - B/3.2 TO 6 & 4.2/C.2 E FROM 4' TO 8' |
|
10/12/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STEM WALLS CMU MASONRY REINFORCEMENT BLDG. #C1 STEEL @ GRID LINES E/3-4.5, 4.5/C.8-F, 4/C-C.8, C/3-5, B/3.2-6 6/B-C & C/3.2-6 AND MASONRY WALLS @ B/3.2-6 TO 4' AFFE |
|
10/09/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
10/08/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
10/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* BLDG #C1 - MASONRY REINFORCEMENT STEEL @ GRID LINE E/2.5 TO 3.5 FROM 8 FOOT TO 12 FOOT AFF |
|
10/04/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
10/01/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU REINFORCEMENT STEEL @ GRID LINES B.1/1 TO 2 1/B.1 TO B.2 & B.2/1-2 FROM 8' TO 9'4" AFFE |
|
09/27/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MASONRY REINFORCEMENT STEEL @ GRID LIINES B.1/1 TO 2 - 1/B.1 TO B.2 - B.2/1 TO 2 TO 8' TO 9'4" LENTEL AND 2.1/C TO D 12' TO 15'4" AFF |
|
09/21/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* BLDG #C-1 - MASONRY REINFORCEMENT STEEL @ GRID LINES E/2.2 TO 3.2 & D/2.1 TO 2.2 TO 8'8" A.F.F.E |
|
09/20/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
09/19/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU WALLS REINFORCEMENT AT GRID E/2.5 TO 3.1 TO 4 FOOT AFF AND 1/B.1 TO B.2-B.1/1 TO 2-B.2/1 TO 2 TO 8 FFOT 8" AFF |
|
09/17/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
09/13/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* BLDG C - 1 @ GRID LINES B/2.1 TO 3 - 3/B TO C @ 8' TO 12' AFF |
|
09/12/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU MASONRY PRE-GROUT @ GRID LINES 3/B TO C - B/2.1 TO 3 @ 8' TO 12' A.F.F.E - 2.1/C TO D - 3/B TO C - B/2.1 TO 3 @ 4' TO 8' A.F.F.E & E/2.5 TO 2.8 @ 0-4' A.F.F.E |
|
09/11/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU MASONRY WALLS FROM 0'-4' A.F.F @ GRID LINE D/2.1-2.5 BLDG C1 |
|
09/06/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED ROAD TO SITE RAINED OUT |
|
07/30/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/30/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* LINE 2.1/C-D, D/2.1-2.5, E/2.5-6, B/2.1-3, 3/B-C |