Permit: T06CM04952

Parcel: 14101008C


Addresses:

10750 E BILBY RD 02


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T06CM04952

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
06/20/2008 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
09/06/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
ROAD TO SITE RAINED OUT
08/30/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU MASONRY WALLS FROM 8' TO 12'7" @
GRID LINE K/4.7 TO 5 - 4.7/J TO K AND COLUMN FOOTINGS @ GRID O/5 & 6 - J/16 & J/1 TO 8 FOOT AND J/5 TO 12'8"
08/29/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EXTERIOR CMU WALLS TO 4'8" @ GRID LINES J/4 TO 4.4
J.2/4.4 TO 4.7
4.7/J.2 TO K
K/4.7 TO 5
K/6 TO 6.3
6.3/J.2 TO K & J.2/6.3 TO 6.5
AND TO 4 FOOT @ O/5 & 6 & J/1 COLUMNS
08/28/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EXTERIOR CMU WALLS AT GRID LINE 4 TO 12'8"/N TO O
O/3 TO 4 - 3/N TO O
M/2.3 TO 3
2.3/L TO M TO 15 FOOT 4 INCH
08/27/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL AT FOLLOWING LOCATIONS LINE 8/J TO O
O/7 TO 8 TO 15 FOOT 4 INCH -- 2/J TO L & L/2 TO 2.3 TO
10 FT 8 INCH
08/24/2007 REINFORCED MASONRY PRE-GROUT Partial Approval BUILDING "B"
CMU WALLS REINFORCEMENT STEEL AT FOLLOWING LOCATIONS GRID LINE J/6.5 TO 8 - N/4 TO 7 - 3/M TO O
M/2.3 TO 3
2.3/L TO M
15 FOOT 4 INCH
12 FOOT 6 INCH
11'4"
O/3-4 TO 11'4"
08/23/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BUILDING "B" REINFORCEMENT STEEL AT CMU WALLS @
GRID LINE M/2.3 TO 3 - 2.3/L TO M - L/2 TO 2.3 - 2/J TO L
TO 4'8" AFF AND J/6.5 TO 8 - 8/J TO O - O/7 TO 8 AND 7/N TO O
TO 11'4" A.F.F
08/22/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
REINFORCEMENT STEEL AT CMU WALL AS FOLLOWS:
GRIDLINE 8/J TO O - O/7 TO 8, 3 TO 4 - N/6.2 TO 7,
4 TO 4.8 - 3/M TO O

FIRST LEFT TO 4'8" - WEST EXTERIOR WALLS FIRST LIFT
TO 4 FEET AFF
08/21/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL 1ST LIFT TO 4FT - GRID LINE 3/M TO O
M/2.3 TO 3 - 2.3/L TO M - L/2. /2.3 - 2/J TO L -- J/4 TO 5
K/6 TO 6.2 -- 6.2/J TO K AND SECOND LIFT TO 8FT @ GRID LINE J/6.5 TO 8 OK TO GROUT
08/20/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) REINFORCEMENT STEEL AT CMU MASONRY WALLS TO 10'-4" AFF BLDG B AT GRID LINE J/6.2-8, 8/J-N-0./3-4 & 7-8 AND N/4-7 OK TO GROUT
08/17/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BLDG "B"
GRID "J"/8 TO 6.5W/JOG @ J TO J.5/6.5
1ST LIFT TO 4 FEET -- OK TO GROUT
06/26/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BUILDING "B" ALL STEM WALLS COMPLETE OK TO GROUT