Permit: T06CM04934

Parcel: 114600260

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM04934

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
01/29/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :
WATER TEST RETEST FOR ROOMS 118-119-109 THRU BUILDING OK WASTE & VENT
01/24/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. NO PIPING SHALL BE DIRECTLY EMBEDDED IN CONCRETE.
2. REMOVE CONCRETE FROM P-6 IN RMS 118-119 AND AT P-3 IN RM 109
3. PROVIDE FOAM WRAP PROTECTION
4. PIPING REPAIRS AND OFFSETS ARE TO BE TESTED.
5. YARD WATER PIPING NOT PER PLAN PROVIDE REDLINE ON PLANS AND PROVIDE A LETTER FROM ENGINEER ALLOWING THIS INSTALLATION AS WELL AS A DETAIL FOR CLEARANCES AROUND BACKFLOW DEVICE.
6. THERE SHOULD BE ROOM A HAND BETWEEN STUCCO AND RP SHUT OFF VALVES
7. PROTECT COPPER FROM STUCCO
8. ALL OTHER AREAS OK TO COVER
9. CLOSET FLANGES OK
01/18/2007 PLUMBING - INTERMEDIATE Cancelled CANCELLED BY ALEX