Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit: T06CM04921

Parcel: 141311580

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/22/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/02/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BROKEN VERT MEMBER GARAGE TRUSS
2) CONTINOUS BEARING END TRUSSES, TRUSSES NOTCHED CLOSER THAN 24" TO HEEL
3) NAIL ALL PANELS TO ROOF
4) SHIM 3 PT AT DIAGONAL WALL
5) SHIM UNDER HEADER BEAM