Date Description Inspector Results Comments
02/22/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/02/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BROKEN VERT MEMBER GARAGE TRUSS
2) CONTINOUS BEARING END TRUSSES, TRUSSES NOTCHED CLOSER THAN 24" TO HEEL
3) NAIL ALL PANELS TO ROOF
4) SHIM 3 PT AT DIAGONAL WALL
5) SHIM UNDER HEADER BEAM