Inspection History Details
Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/22/2007 | SHEET ROCK NAILING | Approved | IVRS - Inspection :* | |
| 05/20/2007 | SHEET ROCK NAILING | Not ready for Inspection | IVRS - Inspection :* | |
| 05/16/2007 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) PENDING LETTER FROM ENGINEER FOR APPROVAL OF REPLACEMENT 1 1/4" SCREWS INTO SAME HOLE AS REMOVED 1" SCREWS FOR SW1 WALLS |
|
| 05/15/2007 | SHEET ROCK NAILING | Cancelled | CANCELLED PER WARREN OF OLLANIK CONST. #260-0047 | |
| 05/14/2007 | SHEET ROCK NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXCEPT TO HOSE BIB 2) 1 1/4" SCREW MINIMUM REQUIRED |
|
| 05/11/2007 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) NOTE: SHEETROCK NAILING APPROVED PER DIRECTION OF STEVE LONG. APPROVED PLAN CALLS FOR 6/D COOLER NAILS 4" ON CENTER AT EDGES AND FIELD SW1 SHEARWALLS 3) PER IRC 2003 PAGE 203 TABLE R702.3.5 FOOTNOTE B. SCREWS SHALL BE TYPE S OR W TYPE G SCREWS INSTALLED |