Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T06CM04901
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/27/2008 | BUILDING PRE-SLAB | Approved | IVRS - Inspection :* | |
05/16/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* | |
05/15/2008 | BUILDING PRE-SLAB | Denied | 1. DETAIL (110) CALLS FOR ALTERNATE BONDS ON REBAR TRUSS 2. DETAIL (112) HAS A TURNDOWN AT EXISTING FOUNDATION 3. DETAIL (104) CALL FOR 2 DOWELS AT EACH EXISTING FOOTING TO NEW FOOTING FOLLOW PLANS OR REVISE |
|
05/13/2008 | BUILDING PRE-SLAB | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REBAR DETAIL 111 CALLS FOR ALT BENDS 2) NEED DOWEL (110) INTO COLUMN FOOTING WITH HORIZONTALS 3) WRAP AND PROTECT ALL PLUMBING TO BE ENCASED IN CONCRETE |