Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06CM04893
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/24/2008 | BUILDING - FINAL | Approved | IVRS - Inspection :* 1) INSULATION CERT NOT NEEDED ICF SYSTEM |
|
09/19/2008 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1. NEED ENGINEERING ON LADDER TO LEFT WITH CITY APPROVED CITY STAMP 2. POST ENERGY EFFICIENCY IN SERVICE PANEL |
|
08/12/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SMOKIES ARE NOT INTERCONNECTED 2) NO ARC FAULT CIRCUITS IN BEDROOM 3) NEED TO SECURE RECEPTACLE AT JACK AND JILL BATH 4) NEED ENGINEERED DETAIL FOR LADDER GOING TO LOFT-THE WIDTH IS UNDER 22" 5) NEED TO COMPLETE FIRE EXTINGUISHER SYSTEM THROUGHOUT HOUSE AND GARAGE 6) NEED ANTI-SIPHON HOSE BIB EAST WALL GARAGE 7) GUEST HOUSE NEEDS ARC FAULT ? 8) NEED TO SECURE HOSE COMING FROM DISHWASHER TO BACK OF CABINET IN GUEST HOUSE 9) ANTI-TIP DEVICE ON RANGE-GUEST HOUSE |