Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM04893
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/24/2008 | FRAMING | Approved | IVRS - Inspection :* | |
01/15/2008 | FRAMING | Partial Approval | IVRS - Inspection :* 1) UNTIL WALL IN 2ND FLOOR IS FRAMED IN (DUE TO SHEETROCK LOADING) 2) OK TO SHEETROCK REST OF HOUSE, RECALL FOR WALL WHEN READY |
|
01/11/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* MAIN HOUSE: 1) FIRE BLOCKING 2ND FLOOR 2) CHANGE 1/2 GAS LINE TO 3/4 3) GROUND WIRE IN RECEPTACLE BOXES 2ND FLOOR |
|
12/21/2007 | FRAMING | Partial Approval | IVRS - Inspection :* INSPECTED GUEST HOUSE ONLY OK TO INSULATE AND SHEETROCK |
|
12/14/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSPECTED GARAGE AND GUEST HOUSE ONLY 2) NEED PROTECTION PLATE ON WIRING ABOVE SERVICE PANEL 3) OK TO DRAIN TUB-DWV HAS BEEN INSPECTED AND OK 4) WAITING ON SPECIAL INSPECTION FOR SPRINKLER SYSTEM |
|
12/11/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING RECEPTACLE PER PLA ON INTERIOR WALL 2) NEED TO PROTECT ALL PLUMBING IN GARAGE WALLS 3) BLOCK DUCT VENTS 3 SIDES 4) MECHANICAL OVERFLOW CANNOT TERMINATE AT KITCHEN DRAIN 5) NEED TO COMPLETE FIRE SPRINKLER PLUMBING 6) MISSING WIRING FOR SMOKE DETECTOR |
|
12/07/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WORK NOT COMPLETE 2) PROVIDE WATER TEST DWV AND POTABLE WATER SYSTEM |