Permit: T06CM04875

Parcel: 123091190


Addresses:

2808 E ADAMS ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/29/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
OK TO COVER ALL AREAS
CALL FOR GAS
11/28/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
NOBODY HOME
11/27/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
- TYPE L COPPER REQUIRED BELOW SLAB.
- HORIZONTAL CHANGES OF DIRECTION IN DRAINAGE PIPING SHALL BE MADE W/WYE PATTERN FITTINGS EQUIVALENT TO 1/8" BEND OR SWEEP OF EQUIVALENT RADIUS.
- ELIMINATE THE USE OF EXCESSIVE 90 DEG. W/45 DEG. FITTINGS WHRE POSSIBLE. ELIMINATE VENT 90 DEG. BELOW FLOOD RIM.
11/17/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. ALL UNDERFLOOR PIPING TO BE SUPPORTED
HAVE 03050 GAS PRESSURE TEST ADDED TO YOUR PERMIT
REMOVE UNUSED PIPING.
2. SUPPORT ALL PIPING ABOVE FLOOR.
3. SOLDERED JOINTS UNDER CONCRETE NOT PERMITTED.
11/14/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. AVB'S ARE NOT INSTALLED UNTIL THE RETAINING SCREW IS BROKEN OFF.
2. HAVE 03050 GAS PRESSURE TEST ADDED TO YOUR PERMIT
HAVE APPROVED GAS PLAN ON SITE.
3. YARDWATER OK TO COVER WITH CLEAN FILL.
4. SOLDERED COPPER JOINTS UNDER SLAB NOT APPROVED.
COPPER IN MASONRY TO BE PROTECTED
5. SLIP NUT TUB DRAIN REQUIRES ACCESS PANEL.
6. CAP OFF ALL OPEN WASTE PIPING - PROVIDE LIGHT FOR UNDER FLOOR INSPECTION.
11/06/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*