Permit: T06CM04855

Parcel: 141310450

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM04855

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/21/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/11/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) A-B2, A-B.D., A-1 B C RAT RUNS
2) ABE SHIM CONT. BEARING
3) SHEAR PANELS MISSING GARAGE BETWEEN TRUSSES
4) NAIL TRUSS PANELS SAME TO ROOF FRONT AND REAR
5) LOOSE PLATE FRONT DESK
6) SHIMMERS ON TOP SIDE ROOF DECK
7) MAS STRAPS WEST AND FRONT
8) WINDO BRACE REAR WALL